Con-Evator

Machine and Alarm list

Description

Cause

Action

Class

Con-Evator

Transport warning

If the transport counts more than X numbers (3 - Standard) of unsuccessful transports, a warning appears.
  1. Missing material.
  2. An unsuccessful transport is if the bottom flap is not down more than 2 sec. (emptying the SVR for material).
  3. Air leaking from pipes.
  4. Suction pipe not adjusted correctly
  5. The slide valve is not opening.
  6. Air leaking from SVR Bottomflap seal.
  1. Check if the material source contains material.
  2. Check if the bottom flap is functioning (both physically and the signal is connected correctly).
    Check the conveying time is set correctly, for full SVR. Adjust time if SVR is not full at each transport.
  3. Check if pipes are leaking.
  4. Adjust suction pipe with the correct airflow
  5. Check if the slide valve is opening and material is flowing through.
  6. Change the bottom flap seal.
Warning

Con-Evator

Motor Alarm

If a motor overloads an alarm appears on the Con-Evator cabinet.
  1. The motor is malfunctioning.
  2. Motor protection is triggered.
  3. Motor protection signal is missing.
  4. Motor is too hot.
  1. Check if the motor is malfunctioning.
  2. Reset Motor protection (see electrical drawings), maybe adjust Amps triggering the protection.
  3. The filter is blocked or the pipe is clogged.
  4. Check if the motor protection signal is connected correct (see electrical drawings).
  5. Let the motor cool down and check if the material is too hot or the blower can't get fresh air.
Alarm

 

Troubleshooting for    DFD    MDFD    Labo-Scan    DH    DMR    Con-Evator    LHD    DDM    Micro-Scan    

For more than 70 years Labotek has supplied quality equipment in various industries, and achieved a deep understanding of our customers' needs. Read about some of the products and solutions we have delivered. We will be happy to share all our know-how within your industry - you are most welcome to contact us for more information.