DH
Machine and Alarm list |
Description |
Cause |
Action |
Class |
DH A1 Over temperature |
If the temperature is more than 15C° above the setpoint for 1 min., an alarm appears. |
|
|
Alarm |
DH A2 Under temperature |
If the temperature is 10C° below the setpoint for 10 min., a warning appears. |
|
|
Warning |
DH A3 Sensor fault dry air |
The alarm is activated if the Pt-100 sensor in the inlet air is disconnected / short-circuited. The alarm turns off the supply of heat. |
Malfunctioning sensor. |
Check if the sensor is working correctly or is short-circuited. |
|
DH A4 Sensor error return air |
The alarm is activated if the Pt-100 sensor in the outlet air is disconnected / short-circuited. The alarm provides only information at the display. |
Malfunctioning sensor. |
Check if the sensor is working correctly or is short-circuited. |
|
DH Regeneration time 2 is too long |
If the regeneration time is longer than 60 min. on molecular sieve 2, a warning appears. | See alarm: REG. TIME 1 IS TOO LONG. | See alarm: REG. TIME 1 IS TOO LONG. | Warning |
DH / Optional alarm A5 Parameter Error Ext. PAR |
The alarm is activated if the option Ext. PAR is used and the parameter value for the setpoint is outside the scaling area. | The parameter value for the setpoint is outside the scaling area. | Check if the scaling / IO from the customer is correct. | |
DH Fire protection |
If the fire protection is triggered an alarm appears and the heating stops. |
|
|
Alarm |
DH / Optional alarm High level |
If the level sensor is activated or not activated (depends on the function) a warning appears. Tells the operator (depending on the function), if the material is at / not at this level in the hopper. |
|
|
Warning |
DH / Optional alarm Middle level |
If the level sensor is activated or not activated (depends on function) a warning appears. Tells the operator (depending on the function), if the material is at / not at this level in the hopper. |
|
|
Warning |
DH / Optional alarm Low level |
If the level sensor is activated or not activated (depends on the function) a warning appears. Tells the operator (depending on the function), if the material is at / not at this level in the hopper. |
|
|
Alarm |
DH Black display |
See alarm: Fire Protection |
See alarm: Fire Protection. |
See alarm: Fire Protection. | Alarm |
Troubleshooting for DFD MDFD Labo-Scan DH DMR Con-Evator LHD DDM Micro-Scan