MDFD
Machine and Alarm list |
Description |
Cause |
Action |
Class |
MDFD Sensor regenerating |
If the regeneration sensor is not showing correct or broken wire. |
|
|
Alarm |
MDFD Regeneration valve position |
If the regeneration valve is placed in the wrong position then expected. |
|
|
Alarm |
MDFD Directional valve position |
If the directional valve is placed in the wrong position then expected. |
|
|
Alarm |
MDFD Outlet temperature to high |
If drying temperature raises above setpoint (80C°) a warning appears. If the drying temperature raises above the 2nd setpoint (85C°), an alarm appears and the dry air blower stops. |
|
|
Alarm |
MDFD Regeneration time too long |
If the regeneration time is longer than 60 min. on molecular sieve 1, a warning appears. |
|
|
Warning |
MDFD Phase order incorrect |
If the phase order is incorrect an alarm appears and the machine stops. | Phase order incorrect. | Check phase direction and correct. | Alarm |
MDFD Fire protection |
If the fire protection is triggered an alarm appears and the machine stops. |
|
|
Alarm |
MDFD Sensor return air - cooler |
If there is an attached return air cooler, there is a max return air temperature setpoint, and if the temperature goes above that, a warning appears. |
|
|
Alarm |
MDFD Sensor process air - cooler |
If there is an attached forward air cooler, there is a max forward air temperature setpoint, and if the temperature goes above that, an alarm appears and stops the dry air motor. |
|
|
Alarm |
MDFD Regeneration air motor alarm |
Regeneration air motor relay disconnected |
|
|
Alarm |
MDFD Forward air motor alarm |
Forward air motor relay disconnected. |
|
|
Alarm |
MDFD Filter Alarm |
If the pressure on each side of the filter is different, a warning appears indicating the filter is blocked. |
|
|
Alarm |